S P Environmental Services has a full range of scale and corrosion inhibitors, pre-commission cleaners, system flush chemicals, and biocides for use in closed circuit heating and chilled systems. This range also contains many specialist products formulated for use in specific specialist or problematic situations. 

Please use our enquiry form for more information or alternatively you can call 0800 799 9406.

 

Product codeApplicationCompositionBenefit
SP202Multi-metal corrosion inhibitorMolybdate / nitrite blendFirst choice premium multi-metal corrosion inhibitor with BuildCert approval. Suitable for hard and soft water.
SP639Multi-metal corrosion inhibitorNitrite and molybdate based formulation.Economical in use. Excellent buffering capacity. Suitable for hard and soft water.
SP589 Multi-metal corrosion inhibitorBlend of corrosion inhibitorsExtremely cost effective formulation. Suitable for hard and soft water.
SP1048 Multi-metal corrosion inhibitor.Molybdate + Blend of corrosion inhibitorsBuildCert approved. Does not contain Nitrite or Boron based additives Suitable for hard and soft water.
SP203 Multi-metal corrosion inhibitor for soft water systemsPhosphate basedIdeally suited to soft water systems. Does not contain nitrite.
SP206 Multi-metal corrosion inhibitor for soft water systemsMolybdate and phosphate basedIdeally suited to soft water systems. Does not contain nitrite.
 

 

Corrosion inhibitors unsuitable for Aluminium

 
Product codeApplicationCompositionBenefit
SP154 Nitrite based inhibitor 1% dose rate.Nitrite and borateAn effective corrosion inhibitor for systems containing steel and 'yellow metal' components.
SP267 Nitrite based inhibitor 1% dose rate. with indicatorNitrite and borateExcellent corrosion control for steel, cast iron, copper and brass. Contains Phenolphthalein as an indicator.
SP205 Nitrite based inhibitor 0.5% dose rate.Nitrite and borateEconomical concentrated formulation. Excellent corrosion control for steel, cast iron, copper and brass
SP889 High conc. product.Nitrite and molybdate basedConcentrated formulation. Excellent corrosion control for steel, cast iron, brass and copper
SP653 High conc. product.Blend of corrosion inhibitorsConcentrated formulation. Dose 0.1% to chilled systems and 0.2% to LPHW systems. An effective corrosion inhibitor for systems containing steel and 'yellow metal' components
SP550 Biostable formulation.Molybdate and borateExcellent corrosion control for steel, copper and brass. Contains a low level of nutrients (no phosphate or nitrite), thus the product does not encourage microbiological growth,
 

Our range includes tannin based closed circuit inhibitors and inhibitors specifically formulated for optimal use in MPHW and District heating systems. Please contact our technical department so that we can help you to pin point the most effective product for use in your system.

CLOSED CIRCUIT BIOCIDES

The main problematic micro-organisms found in closed circuit systems are bacteria, which can lead to the rapid build-up of biofilms in pipework and on heat exchanger surfaces causing reduction in efficiency, flow restrictions and under deposit corrosion.

It is much easier and more cost effective to maintain microbiological control within a closed-circuit system than to clean up a heavy build-up of biofilm.

 
Product codeApplicationCompositionBenefit
SP585 For biocidal flushing and system protection. Can be dosed with high pH inhibitorsProprietaryLow toxicity. Very stable biocide for use with high pH nitrite based inhibitors. Excellent against Pseudomonas ssp. Optimal biocidal activity after 24 – 48 hrs contact. Effective over a pH range pH 8.0 to 11.0. Stable up to 80°C. Test kit available.
SP1532For flushing and system protection. Suitable for the protection of neutral pH systems.ITA blendDoes not contain copper stabiliser. Effective over a pH range of 6.5 to 8.5. Stable up to 50°C.
SP595 For flushing and system protection. Suitable for the protection of neutral pH systems.ITA/BNP blendVery effective against NRB’s Effective over a pH range of 6.5 to 8.5. Stable up to 50°C.
SP105 Suitable for the protection of neutral pH systems.BNPA broad-spectrum bactericide. Low toxicity. Effective over a pH range of 6.0 to 8.0. Stable up to 40°C.
SP1507For flushing and system protection. Suitable for the protection of neutral pH systems.GlutaraldehydeHas a broad spectrum of activity against bacteria and their spores, fungi, also effective against sulphite reducing bacteria (SRB) Effective over a pH range pH 6.5 to 9.0. Stable up to 60°C. Rapid biocidal action.
SP254 For flushing and system protection. Suitable for the protection of neutral and alkaline pH systems.THPSA broad-spectrum product, very effective against SRB’s. Effective over a broad pH Range 3 -10. Stable up to 60°C.
SP1528For flushing and system protection. Suitable for the protection of neutral pH systems.ProprietaryA highly effective non-oxidising biocide containing a synergistic combination of biocides. Ideal for use in closed circuit systems. Effective against, Pseudomonas spp and Sulphate-reducing bacteria. Effective over a pH range of 6.5 to 8.5. Stable up to 50°C.
 

Anti-Freeze

To prevent the recirculating water in chilled systems freezing as outside temperatures get below 0oC in the winter it is often necessary to add antifreeze. It is also important to note that when closed circuits contain 25% glycol or above, the glycol has a biostatic effect i.e. preventing the growth of bacteria. As the concentration falls below 25% glycol can act as a food source for bacteria. As bacteria consume the glycol they produce acidic bi-products lowering the pH of the system and accelerating corrosion.

 
Product codeApplicationCompositionBenefit
SP70 General purpose antifreezeMono ethylene glycol25% Monoethylene Glycol will reduce the freezing point of water down to -11 to -12°C.
SP69 General purpose inhibited antifreezeMono ethylene glycol molybdate based multi-metal inhibitorContains a low toxicity corrosion inhibitor formulation + mono ethylene glycol. Dose at 25% system volume to obtain optimal freeze protection and corrosion control.
SP134Food grade antifreezeMono propylene glycolLow toxicity product. 25% Monopropylene Glycol will reduce the freezing point of water down to -11 to -12°C.
SP133 Food grade antifreeze + inhibitorMono propylene glycol + ‘food safe’ inhibitorContains a low toxicity corrosion inhibitor formulation + mono propylene glycol. Dose at 25% system volume to obtain optimal freeze protection and corrosion control.
 

 

Specialist Closed Circuit Products

 
Product codeApplicationCompositionBenefit
SP891 High conc. Neutral product.Nitrite basedNeutral nitrite additive designed to be added to multi-metal systems where the nitrite component of the inhibitor has been degraded by microbial action.
SP491 pH adjuster and buffer supplement used to decrease the pH in closed circuits where Aluminium is present.A combination of acidic components and bufferSpecialist additive for lowering the pH of alkaline solutions to below pH 8.0 in order to ensure optimal corrosion protection of aluminium.
SP5 Closed Circuit AntifoamMineral oil based antifoamUsed to control foaming in closed systems. Very concentrated formulation
SP139 On-line DescalerA blend of polymers and sequesterantsRemoves the scale responsible for 'kettling' and poor heat transfer. Restores heat transfer efficiency. No system shut down required
SP201 Azole Supplement Suitable for use in open recirculating cooling systems, evaporative condensers and closed water systems.An aqueous solution of azoles.Neutral pH formulation. Systems that have a very large surface area of copper may need additional copper corrosion inhibitor. Can be used as a supplementary treatment to protect copper and brass.
SP916Concentrated azole Supplement Suitable for use in closed water systems.An aqueous solution of azoles.A very high strength solution of benzotriazole. Systems that have a very large surface area of copper may need additional copper corrosion inhibitor.Neutral formulation so addition of this azole supplement will not affect system pH.
SP167Biofilm Dispersant Applications include oil removal in cooling towers and biofilm removal in closed systems.Contains a low foaming surfactant.Compatible with anionic and cationic species. Use in conjunction with an appropriate biocide. Biofilm removed from pipework surfaces will be removed so the system must be assessed prior to use to ensure that dislodged biofilm can be removed from the system efficiently.
 

Pre-Commission cleaning and system flush chemicals

The pre-commission cleaning of hot water heating and chilled systems has become more important over recent years due to the equipment used being more susceptible to blockages at strainers, control valves and small bore heat exchangers. System contaminants such as mill-scale, jointing compounds and fabricating debris need to be removed by chemical cleaning and high velocity flushing, which will then allow the on-going water treatment regime to work effectively in preventing corrosion and microbiological fouling. Older systems that have accumulated deposits due to lack of the correct water treatment can be cleaned by a similar method.

Our range of specialist, effective pre-commission cleaning, biocidal flushing and system flushing chemical formulations are outlined below:

 
Product codeApplicationCompositionBenefit
SP398 Pre-commission & system flushAn aqueous blend of chelants, dispersants and wetting agents.Versatile formulation. Suitable for systems of all ages. Excellent removal of corrosion deposits. Very effective pre-commission cleaner and system flush formulation.
SP850 Pre-commission cleanerA concentrated solution of phosphonate, polymers, chelant and wetting agent.Heavy duty concentrated pre-commission cleaner. Removes oil, grease and flux residues, disperses light iron oxide deposits
SP141 Very low toxicity biodegradeable pre-commission cleanerAn aqueous solution of surfactants, polymers and organic oxygen scavenger.Low toxicity formulation, formulated as a pre-commission cleaner for use on sites where there are restrictive discharge limits
SP140 Pre-commission cleanerBlend of cleaning and dispersing agentsEffectively removes oil, grease and flux residues, disperses light iron oxide deposits. Contains nitrite to passivate bare metal surfaces
SP155 System flush and specialist corrosion removerAn aqueous solution of phosphonates, citric acid, polymers and organic oxygen scavenger.For use in old systems with hard corrosion deposits. Can be left in the system for several weeks. Will remove tightly adhered corrosion debris.Solubilises and disperses iron oxide particles.Passivates cleaned metal surfaces.
SP143 System flushA blend of cleaning and dispersing agents.Blend of cleaning and dispersing agents, lifts and disperses inorganic and organic debris from pipework surfaces.
SP1455On-line cleaner for closed circuit systemsA blend of cleaning and dispersing agents with an effective biodispersant.As this product lifts and mobilises system contaminants including biofilm it should only be used in conjunction with in-line or side stream filtration. Cleans and passivates bare metal surfaces, preventing under deposit corrosion and prolonging system life. Compatible with our full range of closed circuit water treatment LPHW and Chiller formulations.
 

A summary of our core range of products is included above. Many other formulations for closed circuits are also available

Our Technical department is always available for advice on product selection, problem solving and compatibility with other formulations already in use in particular systems.

Customer Testimonials

Lindsey was very helpful in clearly explaining the process of chlorination and water testing, which I had previously had no experience of. From booking the appointments to payments to explaining the results everything was clear and well managed. Would highly recommend.

Harriet Smith

Prompt response to my enquiry. Job was subsequently booked and timescales were very good. Team that attended site were polite and courteous.

Helen Campbell

Great service and very professional. Would highly recommend Jake and his team.

Jack Pickering

Easy to deal with, fast communication and a great overall service both on and off site, happy to recommend.

Kayman

Excellent service, did our chlorination and pressure test within 24hrs of contacting them. Work was carried out in a professional manner and the site was left clean.

Matthew Bebbington

A pleasure to do business with a Company that is efficient and helpful. Both office and site staff were extremely helpful to us in completing our chlorination works.

Paul Hassle

A great service from start to finish. we needed a quick turn around on a site visit and the organisation from Lyndsey was second to none We will be dealing with this company again Thanks Lyndsey and all involved.

Phil Case

Our Customers

Call Us Today for FREE to Discuss Your Requirements with One of our Experienced Team Members 08007999406.

Call Us Today for FREE to discuss your requirements with one of our experienced team members 0800 799 9406.