Closed Loop Analysis

Here at SPES, we can offer our clients with peace of mind that not only do we understand exactly what is right for their systems in terms of chemical treatment, but we also are able to interpret laboratory analysis and trends to understand if there are potential issues within a system closed water system, such as a Heating Circuit (LTHW) or Chilled Circuit (CHW). We have closed system consultants located around the UK and offer free on-site surveys/consultancy. 

Closed System Sampling & Monitoring

On the 30th November 2012 BS 8552 was released; this standard addresses:-

"Sampling and monitoring of water from building services closed systems. Code of practice"

BS 8552:2012 addresses the particular issues of sampling water from closed-circuit heating and cooling systems in buildings and related infrastructure, from construction, pressure testing, pre-commission cleaning and commissioning to routine operation. The purpose of sampling a closed-circuit water system is to provide information about the current condition of that system and/or the water within it. That might include, but is not limited to, water treatment status, water quality, bacteriological contamination and corrosion activity. Confidence in the results obtained, which are crucially dependent on consistent sampling and analysis protocols, is extremely important to industry.

BS 8552:2012 gives recommendations for the design of the sampling programme during each phase of the system lifecycle, including the location and suitability of sampling points, frequency of sampling and recordkeeping, to facilitate the control of closed system water quality throughout the life of the building.
It also gives guidance on:

Procedures for the collection, preservation, handling and storage of samples prior to analysis (by reference to BS EN ISO 56673Water Quality. Sampling. Preservation and handling of water samples; see below); analytical methods (by reference to other British Standards and approved methods )and the statistical treatment of results

The selection of the analytical parameters appropriate to the sampled system and life stage.
Correct maintenance of closed systems will ensure they operate within their design parameters and lifetime, if systems are not correctly treated and maintained then this will lead to unnecessary fuel bills, co2 emissions and eventually system failure.

In summary by using the correct biocide and scale and corrosion inhibitor, heating and chilled water systems can remain efficient and have a longer life span therefore saving the customer on energy and repair bills, if you require testing for your closed systems or maintenance/remedial works please contact admin@spesltd.co.uk or 08007999406

Remain compliant and protect against Legionnaires' disease

Obtain your chlorination certificate for a new development handover

Keep you water systems free from water borne pathogens and sediment 

Complete turn key solutions to keep you water systems compliant 

Closed system flushing, chemical dosing and testing to optimise system efficiency

In house legionella awareness, engineer practical and water testing training services with certification

Chlorinating Mains Water

SPES can carry out Chlorination work to the highest standards within the industry and issue you with the necessary disinfection certifcate. the certificate will give the following Chlorination information.

Find Out More

Chlorinating Down Services

SPES have expertise to carry out disinfections, risk assessments and also advise on best operating practice to clients in order to enable them to maintain high standards of water quality and hygiene.

Find Out More

Water Tank Chlorination

SPES are professionals at water tank chlorination and water tank cleaning, thus leaving you with a clean bacteria free system.

Find Out More

Call Us Today for FREE to discuss your requirements with one of our experienced team members 0800 799 9406.